Magnus Equipment
SEARCH
800.456.6423
4500 Beidler Road
Willoughby, OH 44094

Miji Lif 24 Specifications

Return to Overview

Cleaning Machine Dimensions
MACHINE DIMENSIONS
Machine Number: 24-1X 24-1.5X 24-2X
INSIDE TANK:
Length A 23.5" 36.75" 49.75"
Width B 33.5" 33.5" 33.5"
Depth C 30.5" 30.5" 30.5"
DIPPING SPACE:
Length D 22" 35.25" 48.25"
Width E 22" 22" 22"
Depth F 18" 18" 18"
OVERALL TANK:
Length G 26" 39.25" 52.25"
Width H 36" 36" 36"
Height J 35.5" 35.5" 35.5"
OVERALL MACHINE:
Length G 26" 39.25" 52.25"
Width L 44.5" 44.5" 44.5"
Height M 70.5" 70.5" 70.5"
ROLLER PLATFORM:
Total Length   22" 35" 48"
SOLUTION LEVEL:
Height (above tank bottom): N 23 - 25" 23 - 25" 23 - 25"


SERVICE CONNECTIONS
Machine Number: 24-1X 24-1.5X 24-2X
Drain Valve 1.25" 1.25" 1.25"
Overflow 1" 1" 1"
Air Inlet 3/8" 3/8" 3/8"
Water Inlet 1/2" 1/2" 1/2"
Air Supply (PSI) 60-125 60-125 60-125
Air Consumption (CFM) 3-5 3-5 3-5
Vapor Relief 4" 4" 4"
Average Heat Time (see note #4) 2-4 hrs. 2-4 hrs. 2-4 hrs.


GENERAL DATA
Machine Number: 24-1X 24-1.5X 24-2X
Load Capacity (see notes 1 & 5) 150 lbs. 150 lbs. 150 lbs.
Liquid Capacity (gal) 85 130 170
Tank Wall Thickness #12 ga. #12 ga. #12 ga.
Shipping Weight 500 lbs. 550 lbs. 600 lbs.
Basket Dimensions
BASKET DIMENSIONS (other options available)
Machine Number: 24-1X 24-1.5X 24-2X
Length Y 20" 33" 46"
Width X 20" 20" 20"
Depth Z 8" 8" 8"


HEATING DATA
Machine Number: 24-1X 24-1.5X 24-2X
Electricity: (see note #2) 12kW 12kW 12kW
240V/1/60Hz 50A 50A 50A
240V/3/60Hz 29A 29A 29A
480V/3/60Hz 14.5A 14.5A 14.5A
Steam:
Plate Length 23" 23" 23"
Plate Height 12" 12" 12"
Inlet Pipe 1" 1" 1"
Outlet Pipe 3/4" 3/4" 3/4"


AGITATION DATA
Machine Number: 24-1X 24-1.5X 24-2X
Short Stroke Length 2.5 - 4" 2.5 - 4" 2.5 - 4"
Long Stroke Length (see note #6) In - Out In - Out In - Out
Up & Down Strokes (per min)
Short 120 - 160 120 - 160 120 - 160
Long 20 - 30 20 - 30 20 - 30

NOTES
  1. 450 lb. capacity optional (with overall width .L. 54.5: air consumption of 7 - 11 cfm).
  2. Fully immersed stainless steel sheathed elements will be furnished on all electrically heated units. Other kW voltages and multiple phases on request.
  3. The data shown is typical and may vary with air pressure, load and shape.
  4. From room temperature to 180 F.
  5. Load capacity at maximum psi.
  6. In and out stroke is advantageous in flushing out blind holes in parts.
  7. Maximum part height is 12. - 14. for immersion cleaning agitation

Have additional questions about a product or service?
Contact us at 800-456-6423 or send us an email.

Power Sonics a division of Magnus Equipment